Refregerant Recovery Machine Fully Automatic A/C Refrigerant Filling Machine














AUTOOL LM706 Refregerant Recovery Machine Fully Automatic A/C Refrigerant Filling Machine. The AUTOOL LM706 Refrigerant Filling and Recovery Machine incorporates the most advanced and smart control tech and manufacturing process which is the right assistant tool for auto air conditioning repair and maintenance personnel. It is fully automatic intelligent equipment integrating the functions of refrigerant recovery, vacuuming, refrigerant oil charging and refrigerant filling. This product holds with smart control operation interface, reliable manufacturing process and leading technology principle. It is a preferred auto air conditioning maintenance equipment you highly crave. Notice: The machine is designed to be used and repaired by qualified personnel only. The machine designed for use R12/R134a/R1234yf refrigerant. Do not mix different type of refrigerant otherwise can easily lead to malfunction of the machine. This equipment can only use one kind of refrigerant. If different types of refrigerant are needed, the whole equipment system needs to be emptied. Keep away from moving parts and rotating elements such as cooling fans, alternators and heating components, etc. Wear protective clothing gloves and goggles. As automotive air conditioning pipe flushing, the operator must be fully familiar with automotive air conditioning system and operation of the machine. Check whenever the engine is turned off that the ignition key is turned to the full OFF position! Do not expose the machine to direct sunlight or rain. Use only in well-ventilated work areas. Never exceed 30 ° tilt in transit process upside down is strictly prohibited. Do not touch the machine high voltage power supply section, and do not maintain the machine as power on. Info on refrigerant oil type, the refrigerant oil charge amount, refrigerant type, and the refrigerant charge amount of theair conditioner of the relevant car model can be checked. The refrigerant type can be auto-matched with the corresponding car model. Through this function, the refrigerant in the automobile air conditioning system can be recovered and purified, and stored in the equipment tank to avoid environmental pollution. Select the Recovery function and press the “OK” key to run it. When recovery is finished, the used oil will be drained out automatically. Warning: in the recovery function mode, continuous recovery of liquid refrigerant is strictly prohibited to prevent damage to the freon recovery machine. If you need to recover more than 1.5kg of the liquid refrigerant, please use the replenishment connector or run the refrigerant replenishment function. Through this function, the water vapor and incompressible gas in the A/C system can be completely discharged to maintain the purity of the A/C system. When the equipment detected refrigerant in the air conditioning system, the residual refrigerants should be recovered. Otherwise, there will be a spray phenomenon during the vacuum pumping process, which will easily cause damage to the vacuum pump. If there is a leakage in the air conditioning system, the leakage should be eliminated first. If the system is not sealed for a long time, the service life of the vacuum pump will be reduced. If it displays code as W during the process, please deal with it according to the prompt information. After the operation of the refrigerant recovery tool, there is no need for personnel to take care of it until it is finished by itself. Through this function, a proper amount of refrigerant oil is injected into the automobile air conditioning system to maintain the air conditioning performance. NOTE: The amount of refrigeration oil added to the new oil bottle should be more than 20ml more than the amount of old oil discharged. During the filling process, the new oil level should not be lower than the suction pipe opening in the oil bottle to prevent air from entering the air conditioning system. When the car air conditioning system is in a non-vacuum state, it will not be able to perform the function of adding new oil. Select the Fill new oil function. It can be filled by manual control or by setting the filling amount. If the manual filling mode is selected, press the “OK” key once to fill about 510ml; or press and hold it to continuously fill; If the automatic filling mode is selected, set the filling amount, and then press “OK” to run. NOTE: In the process of new oil filling, do not take the oil bottle and shake the ac recovery machine, otherwise it will lead to the inaccurate filling! Through this function, the refrigerant can be quantitatively filled into the automobile air conditioning system. The recharging amount setting: Method 1: Set the amount directly. Method 2: Set the amount by the database. Steps as follows: Under the setting interface, press the? ” key to enter the database interface, Select the brand, model and model year, press “OK to confirm, and the filling amount will be set automatically. NOTE: In order to ensure the normal operation of the filling function, the reserved amount of refrigerant in the equipment tank is set to 1kg, and the setting value of the filling amount is: the amount of refrigerant in the tank minus 1kg. If the refrigerant quantity in the tank is 1.2kg, the maximum setting value of filling quantity is 1.2-1 = 0.2kg. Tip: In the recharging process, if the interface appears Please start the A/C. , it means that the liquid refrigerant inside the ac recovery machine is insufficient and impossible to continue filling in the normal pressure difference method. At this time, it is necessary to turn on the air-conditioning to complete the recharging process. After setting the relevant parameters, the entire replacing process does not require manual operation. The entire operation can be done through the touch panel. With the large LCD display, its operation process and data can be seen at a glance. With self-protection features, the device will automatically stop and alarm when there is a problem with the replacing process. Enables accurate refrigerant recovery. Precisely weighing the refrigerant amount. Oil and air can be automatically separated and collected through separate tubes to ensure separate recovery of vapor and liquid. 1pc AUTOOL LM 706 Fully Automatic Refrigerant Filling Machine main unit. 1pc Working Hoses Red and Blue (3m). 2pc Seals for hose. 1pc Couplers (High & Low pressure). Usually we use E-packet, sometimes DHL/EMS and other Excellent Service is used per customers’ request. For those who are outside US. HK POST/SG POST/ DHL /EMS ect. It all depends on our customers’ choices. Hope we can deal with soon and let us witness this moment. Welcome to our store! We are Mrcartool, a professional automotive repair and maintain enterprise. Our own factory and chain repair shop located in China. We supply many products on Automobile consumer electronics, such as coder reader, diagnostic tool, GPS, DVR, bluetooth. Kit, injector cleaner and battery system tester etc. High product quality, reasonable prices, excellent customer service and a reliable credit standing is our target. Feedback is very important to us. It is impossible to address issues if we do not know about them! This item is in the category “eBay Motors\Automotive Tools & Supplies\Shop Equipment & Supplies\Other Shop Equipment”. The seller is “mrcartool” and is located in this country: US. This item can be shipped to United States.
- Brand: AUTOOL
- Manufacturer Part Number: AUTOOL LM 706 Fully Automatic Refrigerant Filling Machine
- Type: Refregerant Recovery Machine
- Warranty: 3 Year
- Country/Region of Manufacture: China
- Function 1: Refrigerant Recycle & Purity
- Function 2: Used Refrigerant Oil Discharge
- Function 3: Adjustable Refrigerant Filling
- Function 4: Scheduled Vacuuming
- Function 5: Adjustable Oil Filling
- Feature 1: Fully Automotic Operation
- Feature 2: Self-Protection
- Feature 3: Smart Control Panel
- Feature 4: Interior Design
- Feature 5: Built-in Database
- Functio6: Auto. Mode
- Ambient Temp.: 0-50°C
- Input Voltage: AC 110V
- Compressor Displacement: 12.12cm3
- Accuracy Of Steel Cyl Electronic Scale: 30kg土10g
- Refrigerant Tank Capacity: 12L
- Accuracy Of Oil Bottle Electronic Scale: 10ml
- New Oil Bottle Capacity: 300ml
- Used oil Bottle Capacity: 300ml
- Language: Chinese, English
- HP Meter Range: -1bar ~3.5MPa
- TP Gauge Range: -1bar-3.5MPa
- Relative Humidity: <85%
- Vacuum Pump: 7.2m3/h, 5Pa
- Max Working Pressure: 20bar
- LP Meter Range: ( -1bar- 2.5MPa
- Filling Hose: 3m*2